Online Measuring Of Grain Flowrates and Its Measurement Sensitivities with Pitch and Roll Angles
DOI:
https://doi.org/10.25077/aijans.v2.i02.45-56.2021Keywords:
Crop Yield Mapping, Microwave Flow Sensor, Flow Sensor Calibration, Flow Measurement AccuracyAbstract
A complete calibration test stand was constructed and instrumented to examine the effect of varying pitch and roll positions on the measurement errors of a microwave solid type flow sensor. Results indicated that measurement errors ranging from 2.50% to 6.82% and 1.80% to 8.86% were obtained by the changing of chute pitch (descending and ascending) and roll angle positions from 1.5° to 4.5°, respectively. Greater measurement errors were found at the low screw auger conveyor speed range. However, the magnitude of errors is within the acceptable margin for any typical wet paddy land topography.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Reni Eka Putri, Azmi Yahya, Nor Maria Adam, Samsuzana Abd Aziz